Update the firmware on your scanner!

Why would you want to update the firmware on your scanner, and how do you do it?
First, let’s explain WHAT firmware is. Firmware is the operating system of your radio, it works behind the scenes and tells the radio how to deal with things like keyboard inputs, frequencies, etc. Just like your computer or phone has an operating system (Like Windows 10, iOS etc.) scanners do too. Remember, scanners these days are miniature computers; they work much in the same way.

Firmware updates are released for a couple reasons. They either fix a problem or add/change features. Sometimes they do both. As an example, the BCD436HP’s most recent firmware update added the ability to add ProVoice and DMR digital protocols, before that firmware updates addressed an issue with clock settings.

When updating firmware one must follow ALL instructions CAREFULLY! You have the possibility of “bricking” your radio if you don’t do it right. This means that your $500 scanner may now be more useful as a brick than a radio… Follow the provided instructions to the letter and make sure that the program and firmware file you use is intended for your radio. The firmware for the PRO106 will not work on the WS1040!

Before trying to update the firmware on your radio make sure you have properly downloaded the firmware file itself as well as the installation program (if needed) BEFORE you start. If you do not have a replacement firmware file to install do not start the process since this erases the existing firmware to make the radio ready for the new version. No new version means no radio once you get going.

Some radios firmware updates are easier than others. The HomePatrol type radios use a program called Sentinel to check for new firmware versions and install them (easy, safe). Other Uniden scanners use a “Bearcat Version Updater” program to install a new update. GRE/RadioShack/Whistler scanners also use an application to install new firmware versions (nerve-wracking maybe).

What they all have in common is that they require a computer running Windows to update. (You can do it with a Mac running Windows with Parallels, Fusion, Bootcamp etc.) You also need the appropriate cable to connect from your computer to the radio. This is usually done via USB but some older radios use a Serial port.

Before updating your firmware make sure you have the following on hand:
• The radio you want to update
• The proper cable for your radio, along with the drivers already installed (if needed)
• The Firmware Updating program appropriate for your radio
• The actual firmware file itself (Imperative!)
• A strong sedative or plenty of alcohol to calm your nerves (optional)

Follow the instructions included with the firmware update TO THE LETTER. Make sure your radio and the computer can communicate properly. If you have programming software for your radio then read it first and save the programming file just in case you need to restore it to the radio. This also ensures that the radio and computer can communicate.

We also suggest that you check the RadioReference forum for your radio to see what other people’s experiences have been. Reading about someone else’s mistake is a lot easier than trying to fix your own.

Owners of PRO651 and PRO652 scanners that had tried to update their radios’ firmware versions had issues since no firmware updates were available until recently. Now one can download them and install them so previously bricked radios can be reincarnated.

ScannerMaster can update the firmware on many different models of scanners. Download the Hometown Programming Form for your radio and check the Firmware Update option if you would prefer our expert programmers to do this for you. We keep them heavily sedated all of the time already so their nerves are steady. Firmware Updates for “Zip Code Scanners” (HomePatrol, 436/536 and the TRX/WS1080/1088/1095/1098 series scanners) is included with the Setup and Optimize package already, it is an extra cost option for other scanners. If you aren’t sure call us and we will let you know.

Software UPDATE: ARCXT Software V.2.1 Build 3

BuTel ARCXT Software update is now available
Download here ARCXT Basic / ARCXT PRO

BuTelChanges in 2.1 build 3:

  • added support for DMR/Mototrbo systems
  • added talk group filters to RR import
  • added service type filters to RR import
  • fixed error message in RR import
  • add print group quick keys option
  • added Color code settings to DL/DPL

DMR/ProVoice firmware update information 

Note:
Owners of the BCD325P2 and BCD996P2 must update the scanner firmware in order to use the new ARCXT update.  This is only for P2 models and does not effect XT models.

BCD325P2 Firmware Updates
BCD996P2 Firmware Updates

AOR DV1 Firmware Alert

The AOR DV1 has another new firmware update (v1507f) available at http://www.aorusa.com/support/firmware.html.

Below are the updates included in this release. Future releases will address other issues. Please contact AOR directly at http://www.aorusa.com/ with questions and suggestions.

The installation instructions are fairly simple, copy the firmware file to the SD Card, turn the radio on and press a couple keys. The instructions are included with the file.

Following features have been implemented:

* Backup to and restore from SD card

Following bugs have been removed:
* Fixed “auto-store” bug when SEARCH is running.
* S-Meter indicator stayed sometimes on even though power was off.
* When the file 99999999.wav was present in the SD card, the next recording was mistakenly named 10000000.wav. Now the recording after 99999999.wav is made impossible.
* Priority receive was not always functioning.
* Could not go out of settings screen after priority receive activation.
* Receiver would not restart properly if the function key was pressed before switching the receiver off.
* Invalid characters on LCD when time settings accessed during memory receive.
* Incorrect memory channel content switch when priority mode was activated during memory scan
* When erasing a search bank the LCD froze on “writing” indication.
* Memory bank editing was not possible during SCAN.
* Erasing search bank 39 in search group settings was impossible.
* Auto-store function: If memory bank 39 was full, channels 46 to 49 were not kept in memory after a reboot.
* Invalid characters on screen when “writing” was displayed.

FUNCTIONS AND BEHAVIOR CHANGES:
* When SEARCH is stopped and the [ENT] key pressed, the currently received frequency and settings are copied to VFO-Z.
* VOL/SQL maximum value changed from 100 to 99.
* (PC remote control through Hyperterminal commands). When receiver is turned off with the QP command and USB cable disconnected, the next time the receiver is turned on through the front panel, it will start in a “non-remote control” state.

Firmware Alert – Uniden HomePatrol-1 [2.03.01]


By Jonathan Higgins

Product: Uniden HomePatrol-1 (HP-1)
Firmware Update: 2.03.01

What included in the update?

  • Improved the SD Card Error message to help resolve troubleshooting issues.
  • Added a low-pass filter switch option for raw data output mode.
  • Added a remote command to control the low-pass filter switch.
  • Fixed the issue where the display mode setting was reset after cycling power.
  • Fixed that some systems were not appearing in Add Channel mode.
  • More details

    This update should fix a couple of the little bugs that were reported to Uniden. Nothing major in this update.
How to update your HomePatrol?

  1. Plug your HP-1 into AC Power to prevent power lost during update.
  2. Connect your HP-1 to your PC via the Programming cable.
  3. Open the Sentinel Software
    (If you don’t have the software download it here)
  4. Click “Update” tab
  5. Select “Update Firmware”
  6. Your HomePatrol should be selected, click “OK”
  7. The software will prompt you once the download is done.
  8. Disconnect the programming cable from your HP-1
  9. Please allow a few minutes for the update process to run.
  10. Your HP-1 will restart and the firmware update is complete.

Scanner 101 – Installing New Firmware for the BC125AT

Firmware Update
Download Firmware Update 1.02.05 (April 26, 2012)

This update makes the following changes:

  • Update the frequency steps in the VHF band to match the latest FCC Narrowbanding band plan.
  • Change the opening screen to include the current firmware version.
  • Apply a one-time routine to convert the memory image of existing channels to the new format required by the narrowbanding change.
  • Change how Marine channels are displayed during service search.
  • Fixed a bug that could cause scanning/reception to stop with certain combinations of Close Call and other features selected.

Directions using Internet Explorer and Windows7 as the operating system

Step 1
Download the Firmware loader for the BC125AT – Download here

Step 2
When download prompt pops up select “Open”
(this will take a few minutes to download)

Step 3
A window will pop up select BC_VUP_V3_00_01 folder

Step 4
Select Setup_BC_VUP.msi and then click run

Step 5
Click close on the Installation Complete window

Step 6
Open the Firmware loader in programs under Uniden , then BC_VUP3

Step 7
When software opens a “Select Model” window should appear. As seen in the photo bellow.
Click Next
BC125AT-Soft001 Step 8
At this point you should have your Uniden BC125At turn on and connected to the PC via the data/power cable. Once this is done Click “OK” (Note: Uniden BC125AT drivers must be installed – Click here for directions)

BC125AT-Soft002
Step 9

Click “Auto Detect”, when the comport is detected then click “Next”

BC125AT-Soft003 Step 10
Click read and then click “Start”
BC125AT-Soft004Step 11
It will take about 3 minutes for the new firmware to be written to your BC125AT Scanner. Once you see the screen bellow your firmware update is complete.
BC125AT-Soft005

 

Firmware Alert – Uniden HomePatrol-1

By Jonathan Higgins

Product: Uniden HomePatrol-1 (HP-1)
Firmware Update: 1.03.01

What included in the update?

This update should fix a couple of the little bugs that were reported to Uniden. Nothing major in this update.

How to update your HomePatrol?

  1. Plug your HP-1 into AC Power to prevent power lost during update.
  2. Connect your HP-1 to your PC via the Programming cable.
  3. Open the Sentinel Software
    (If you don’t have the software download it here)
  4. Click “Update” tab
  5. Select “Update Firmware”
  6. Your HomePatrol should be selected, click “OK”
  7. The software will prompt you once the download is done.
  8. Disconnect the programming cable from your HP-1
  9. Please allow a few minutes for the update process to run.